夜夜爽夜夜叫夜夜高潮漏水,13小男生GAY自慰脱裤子,亚洲国产精品美女久久久久AV,中文字幕丰满乱孑伦无码专区

產品列表PRODUCTS LIST

首頁>產品中心>日本光明北川式氣體檢測管>氣體快速檢測管>240S硅烷SiH4氣體檢測管240S SILANE 0.5-50ppm

硅烷SiH4氣體檢測管240S SILANE 0.5-50ppm

簡要描述:

硅烷SiH4氣體檢測管240S SILANE 0.5-50ppm,化學性質:硅烷是一種無色、與空氣反應并會引起窒息的氣體,同義名稱:四氫化硅(Silicon hydride) Tube Nos. 1HH, 2HT, all 6, 6L, 6LP, 6LLP, all 11, 11L, 11LA, 11S, 11HA, all 15, 15L, 15H, 19LA, 25, 26, 27, 45S, 45H, 51, 51H, 51L, 52, 53, 70, 70L, 76M, 77, 107

更新時間:2024-12-19

發郵件給我們:554328895@qq.com

分享到: 1
在線留言
硅烷SiH4氣體檢測管240S SILANE 0.5-50ppm

硅烷SiH4氣體檢測管240S SILANE 0.5-50ppm

Tube No.240S
1. PERFORMANCE
1) Measuring range :1-50 ppm 0.5-25 ppm
Number of pump strokes 1(100ml) 2(200ml)
2) Sampling time :5 minutes/1 pump stroke
3) Detectable limit :0.3 ppm(200ml)
4) Shelf life :1 year (Necessary to store in a refrigerated place ; 0~10℃)
5) Operating temperature :0~40℃
6) Temperature compensation :Necessary under 20℃(See "TEMPERATURE CORRECTION TABLE")
7) Reading :Direct reading from the scale calibrated by 1 pump stroke
8) Colour change :Yellow→Red
2. RELATIVE STANDARD DEVIATION
RSD-low:10% RSD-mid.:10% RSD-high:10%
3. CHEMICAL REACTION
By reacting with Mercuric chloride, Hydrogen chloride is liberated and PH indicator is discoloured.
SiH4+HgCI2→HCI
4. CALIBRATION OF THE TUBE
STANDARD GAS CYLINDER METHOD
5. INTERFERENCE AND CROSS SENSITIVITY
50
40
30
20
10
5
2 1 GAS To pump
240S SILANE
Substance Interference ppm Coexistence
Phosphine 2re lda ysetarsin o af rger epyroisdhu wcehdit.e and 20 Higher readings are given.
Arsine 2st alainye arrse o pf rdoadrukc berdo.wn and red 50 〃
Disilane A Similar stain is produced. 2 〃
Diborane 〃20 〃
Ammonia 100 Lower readings are given.
Whole reagent is changed to orange. But
Sulphur dioxide the accuracy of readings are not affected
by Sulphur dioxide if the top of the stained
layer is clear.
IPA Not affected.
Hydrogen 〃
Hydrogen chloride 250 Not affected.
Dichlorosilane 200 〃
(NOTE)
In case of 2 pump strokes, following formula is available for the actual concentration.
Actual concentration=Temperature corrected value×1/2
TEMPERATURE CORRECTION TABLE
Scale True Concentration (ppm)
Readings 0℃ 10℃ 20-40℃
(ppm) (32°F) (50°F) (68-104°F)
50 38 45 50
40 30 35 40
30 22 26 30
20 14 17 20
10 7 8 10
5 4 4 5
2 2 2 2
1 1 1 1