乙二醇HOCH2CH2OH氣體檢測(cè)管232SB ETHYLENE GLYCOL 3-40mg/m3,氣體檢測(cè)技術(shù)只需使用檢測(cè)管和采集器就可對(duì)氣體進(jìn)行檢測(cè)。操作簡(jiǎn)單,極易掌握,有著廣泛的應(yīng)用,可以在很多領(lǐng)域發(fā)揮作用。其中包括:重工業(yè):鋼鐵、造船、汽車、造紙等,制造業(yè):食品、家電、半導(dǎo)體等,石化業(yè):化學(xué)工業(yè)、石油精煉等,能源領(lǐng)域:天然氣、電力等,工程施工現(xiàn)場(chǎng):下水道、燃?xì)夤こ獭⒔ㄔO(shè)工地等,科研:研究室、實(shí)驗(yàn)室等
更新時(shí)間:2024-12-18
在線留言乙二醇HOCH2CH2OH氣體檢測(cè)管232SB ETHYLENE GLYCOL 3-40mg/m3
Tube No.232SB
1. PERFORMANCE
1) Measuring range :3-40mg/m3
Number of pump strokes 3(300ml)
2) Sampling time :4.5 minutes/3 pump strokes
3) Detectable limit :1mg/m3
4) Shelf life :3 years
5) Operating temperature :15~40℃
6) Temperature compensation :Necessary(See "TEMPERATURE CORRECTION TABLE")
7) Reading :Direct reading from the scale calibrated by 3 pump strokes
8) Colour change :Pale pink→Yellow
2. RELATIVE STANDARD DEVIATION
RSD-low:10% RSD-mid.:10% RSD-high:10%
3. CHEMICAL REACTION
By decomposing with an Oxidizer, Formic acid is produced and PH indicator is discoloured.
HOCH2CH2OH+HIO4→2HCHO+HIO3+H2O
HCHO+HIO4+H2SO4→HCOOH+HIO3
HCOOH+NaOH→Na(HCOO)+H2O
4. CALIBRATION OF THE TUBE
GAS CHROMATOGRAPHY
5. INTERFERENCE AND CROSS SENSITIVITY
?? ??
GAS To pump
DETECTOR TUBE
(White)
PRETREAT TUBE
40
30
20
10
5 3
300ml
mg/m3
232SB ETHYLENE GLYCOL
Substance Interference Coexistence
Aldehydes Similar stain is produced. Higher readings are given.
Sulphur dioxide Brownish yellow stain is produced. 〃
Hydrogen sulphide 〃〃
TEMPERATURE CORRECTION TABLE
Scale True Concentration (mg/m3)
Readings 15℃ 20℃ 30℃ 40℃
(mg/m3) (68°F) (71.6°F) (77°F) (86°F)
40 67 40 32 25
30 50 30 24 19
20 34 20 16 12
10 17 10 8 6
5 8 5 4 3
3 5 3 2.5 2